top of page

ENDOSCOPIC SYSTEM VENA SAFENA

VirtuoSaph® Plus

The VirtuoSaph Plus System covers all aspects of the vein removal procedure - from initial incision to vein removal - to provide an optimal conduit.

The VirtuoSaph Plus EVH system design was developed through a thorough process of research and refinement. It was optimized for the performance of systematic and successful saphenous vein and radial artery removal for coronary artery bypass graft (CABG) and peripheral artery bypass graft procedures.

The VirtuoSaph Plus EVH System helps your operating room (OR) perform successful EVH procedures through:

img_500x780_technique.png
SISTEMA ENDOSCÓPICO VENA SAFENA: Product
  • Open CO 2 system with distal insufflation reduces the risk of retained clots and provides a conduit that retains its native moisture 1

  • Bipolar electrosurgical energy supplies high-frequency electrical currents and voltage through an active electrode, causing desiccation and vaporization of only the target tissue at the point of contact, so that damage to sensitive tissues can be avoided close to the instrument and patient burns are virtually eliminated 2

  • The 'shear triad' (tunnel wall grounding, low wattage and stiffness of the branch) provides fast and precise coagulation between the branches of the vessel and the tunnel wall, controlling the direction of energy away from the conduit , which produces less thermal dispersion.

  • Unique built-in wiper mechanism cleans endoscope lens to improve visibility during harvest

  • Integrated point cautery with built-in safety switch activates in one step to control hemostasis when needed

  • Non-cumbersome design reduces number of components, connections, and procedural steps to improve OR efficiency

img_500x780_technique.png

Method

Clinical evidence shows that the VirtuoSaph endoscopic saphenous vein removal technique preserves the structural and functional viability of the SV endothelium. 3

Dissector

The patented PTFE sleeve dissector reduces friction in narrow muscle anatomy. Provides consistent and uniform dissection of the saphenous vein, radial artery, and surrounding branches.

img_500x780_dissector.png
img_500x780_harvester.png

Reaper

The harvester coagulates and cuts the branches of the saphenous vein or radial artery in one step. The ergonomic handle design allows one-handed operation of the device for comfort and ease of use.

Barter

When used with the dissector and harvester, the trocar will allow constant advancement through the tunnel and minimize pressure on the vessel at the incision site.

img_500x780_trocar.png
SISTEMA ENDOSCÓPICO VENA SAFENA: Características
SISTEMA ENDOSCÓPICO VENA SAFENA: Galería de fotos
bottom of page